Feel Secure with ERRC and BDA Systems
In an emergency situation, like a widespread fire or gas leak, first responders rely on two-way radio communication to coordinate their response. However, common building materials such as concrete, steel, metal framing, and low-emission (low-E) glass can weaken radio frequency (RF) signals as they travel through a building. Below-grade areas, stairwells, elevator lobbies, mechanical spaces, and parking garages can be especially difficult for radio signals to reach.
An emergency responder radio coverage (ERRC) system, also known in current codes as an emergency responder communications enhancement system (ERCES), improves public safety radio coverage in areas where the existing signal cannot reliably penetrate the building. These systems commonly use a bi-directional amplifier (BDA) and distributed antenna system (DAS) to receive, amplify, and redistribute radio signals throughout the property.
ERRC and ERCES requirements are set by fire codes, standards, and local regulations. The 2024 International Fire Code addresses these systems in Section 510 and refers to NFPA 1225 for public safety communications. Requirements can vary by location. Your local Authority Having Jurisdiction and public safety radio system rules may affect coverage, system design, permits, testing, and final approval. At Solid Security, we follow these requirements at every stage, from evaluation and design to installation and testing.
Our ERRC & BDA System Services
Step 1: Schedule a Free Consultation
If you have been told your building needs a public safety radio coverage test, or if your property did not pass a recent inspection, Solid Security can help you plan what to do next.
We evaluate in-building radio coverage to find areas where emergency responder communications do not meet required standards. If coverage is not adequate, we work with you to develop a solution that fits your building, the public safety radio network, and local requirements.
Contact us to schedule an evaluation or discuss the results of a recent inspection.
Step 2: We Create a Solution for You
Our team evaluates your property to determine whether existing public safety radio signals provide adequate coverage throughout the building. RF testing can identify areas where signal strength or quality falls below applicable requirements.
If an enhancement system is needed, we’ll design a solution based on factors such as your building’s layout and construction, identified coverage gaps, public safety radio frequencies, and local AHJ requirements.
Depending on the project, the system may include a donor antenna, BDA, distributed interior antennas, cabling, backup power, and monitoring equipment.
Our team handles the system design and installation and coordinates required testing and compliance procedures.
Step 3: Enjoy Peace of Mind
After installation, the system must be tested to verify that it provides the required radio coverage and performance throughout the building. Testing typically involves taking measurements at multiple locations and confirming system operation, signal performance, backup power, and monitoring functions.
Once your system is operational, Solid Security can provide ongoing inspections, maintenance, and repairs to help keep it performing as designed.
“…very accommodating…”
“Charlie was awesome, very accommodating, and did everything we asked, and had a great attitude the whole time.”
– James
Why Choose Solid Security
An ERRC system is more than an amplifier. Its performance depends on proper RF testing, system design, installation, configuration, and coordination with applicable public safety requirements.
Solid Security provides comprehensive ERRC and BDA services, from initial building evaluation and system design through installation, testing, and ongoing maintenance. Our team works with the unique characteristics of your building and the requirements of the local AHJ to develop an effective solution.
When you entrust Solid Security with your property’s emergency communication needs, you discover where innovation meets integrity.
These terms describe related but different parts of an in-building public safety radio solution.
ERRC refers to emergency responder radio coverage, while ERCES refers to an emergency responder communications enhancement system. ERCES is terminology used in newer codes and standards for systems that improve emergency responder communications inside buildings.
A BDA, or bi-directional amplifier, is equipment used to amplify radio signals in both directions. A DAS, or distributed antenna system, is the network of antennas and cabling that distributes those signals throughout the building.
A complete public safety communication enhancement system may use a BDA and DAS together to provide the required coverage.
Applicable editions of the IFC use a minimum of 95% coverage in general areas and 99% coverage in designated critical areas. Critical areas can include locations such as exit stairs, exit passageways, elevator lobbies, fire command centers, fire pump rooms, and sprinkler control valve locations.
However, the exact criteria for a property depend on the adopted code, public safety radio system, and requirements established by the local AHJ. Signal strength alone may also be insufficient to demonstrate compliant coverage; signal quality and the ability to reliably transmit and receive communications can be part of the evaluation.
Testing evaluates whether the system continues to provide adequate public safety radio communication throughout the required areas of the building.
Depending on the applicable requirements, technicians may:
- Measure RF signal strength and quality throughout the building
- Verify inbound and outbound radio communication
- Inspect donor and distributed antennas
- Inspect cables, connections, and system components
- Test battery or secondary power
- Confirm required supervisory and trouble signals
- Check system frequencies and configuration
- Document results for the building owner and AHJ
Testing requirements can vary by jurisdiction and system.
Yes. An ERRC/ERCES is a life safety system. Regular testing is necessary to ensure it continues to provide the radio coverage emergency responders rely on inside your building.
IFC requirements call for annual inspection and testing of these systems. Additional testing is needed after any additions, renovations, or structural changes that could affect radio coverage. This process can include an in-building radio coverage test, verification of BDA performance, checks of backup batteries and power supplies, and inspection of active system components.
Inspections matter because a system that passed at installation may not perform the same way over time. Changes to the building, system components, antennas, batteries, or the public safety radio environment can all impact performance.
Specific inspection, testing, documentation, and reporting requirements depend on the code your jurisdiction has adopted and your local AHJ. Solid Security can provide ongoing testing, maintenance, and repairs to help keep your system operational and ready for its next inspection.
The Authority Having Jurisdiction, or AHJ, is the organization or official responsible for enforcing applicable codes and approving a system. Depending on the location and project, this may include the local fire marshal, fire department, building department, or another code official.
The AHJ can establish requirements for radio frequencies, coverage, system design, permitting, testing, documentation, and final acceptance. That’s why ERRC requirements can differ between jurisdictions.
Whether a building needs an ERRC system depends primarily on whether adequate public safety radio coverage exists throughout the property and on the requirements of the local AHJ.
Coverage problems are commonly found in:
- High-rise and multi-family buildings
- Underground parking facilities
- Large commercial and industrial properties
- Buildings using low-E glass
- Concrete and steel structures
- Below-grade spaces
- Stairwells and other enclosed critical areas
An RF coverage evaluation can determine whether the existing public safety radio signal meets applicable requirements or whether an enhancement system is necessary.
A bi-directional amplifier (BDA) receives and amplifies radio signals traveling both into and out of a building. In a public safety ERRC system, the BDA is typically connected to an exterior donor antenna and an interior distributed antenna system.
The donor antenna receives the public safety radio signal, the BDA amplifies it, and the DAS distributes it throughout areas of the building that need enhanced coverage. The process also works in the opposite direction, helping transmissions from emergency responder radios inside the building reach the public safety radio network.
Public safety BDA systems should not be confused with commercial cellular signal boosters. Although both technologies can improve RF coverage, public safety systems operate on designated emergency communication frequencies and are subject to specific code, equipment, testing, and AHJ requirements.